Efectividad clínica de la tomografía computarizada de 64 detectores en el estudio pre y postquirúrgico de pacientes candidatos y portadores de implantes cocleares respectivamente

dc.contributor
Universitat Autònoma de Barcelona. Departament de Medicina
dc.contributor.author
Puyalto De Pablo, Paloma
dc.date.accessioned
2015-07-07T08:28:49Z
dc.date.available
2015-07-07T08:28:49Z
dc.date.issued
2015-06-12
dc.identifier.isbn
9788449053566
cat
dc.identifier.uri
http://hdl.handle.net/10803/298309
dc.description.abstract
Los implantes cocleares son unos dispositivos en forma de transductores que transforman las señales acústicas en señales eléctricas y estimulan al nervio coclear. Están indicados en aquellos pacientes que sufren una sordera neurosensorial uni o bilateral, profunda o total, y que no se benefician de una prótesis auditiva. En la valoración radiológica prequirúrgica es imperativa la realización de una TC y una RM del hueso temporal. La introducción de las TCMD de 64 detectores, ha aumentado la calidad de la imagen, al realizar secciones de hasta 0,625 mm, lo que permite un estudio detallado de la anatomía del oído, la realización de reconstrucciones multiplanares postprocesado 2D lineales, curvas, visiones endoscópicas virtuales y 3D. Actualmente existen implantes cocleares de diferentes longitudes. Son necesarias técnicas de imagen de alta resolución y sistemas de postprocesado que permitan hacer un estudio exhaustivo de la morfología de la cóclea y su longitud para poder seleccionar el implante más adecuado (forma, longitud y número de electrodos) para cada paciente y determinar la profundidad de inserción adecuada. La hipótesis de la presente tesis fue que la TCMD es capaz de medir la longitud de la cóclea de forma fiable con la finalidad de seleccionar el implante del tamaño más adecuado para cada paciente y conseguir los mejores resultados auditivos posibles. Los objetivos principales de la presente tesis fueron: estudiar la anatomía radiológica de las estructuras del hueso temporal implicadas en el proceso de implantación y validar el método de cálculo de la longitud de la cóclea y del implante a partir del estudio de oídos estándar de TCMD. Los objetivos secundarios fueron: determinar qué variables (anatómicas, epidemiológicas, radiológicas y/o quirúrgicas) se relacionan con los mejores resultados auditivos en los pacientes implantados y valorar cuál es el mejor sistema de postprocesado que permite la medición más exacta de la longitud de la cóclea y/o implante. Para ello se llevó a cabo un estudio observacional, retrospectivo, de los 50 pacientes a los que se ha colocado un implante coclear en el Hospital Universitari Germans Trias i Pujol desde enero 2007 hasta junio 2014 que cumplían todos los criterios de inclusión y ninguno de exclusión, mediante la recogida de variables anatomoradiológicas, epidemiológicas , quirúrgicas y funcionales. Los resultados obtenidos permitieron concluir que la variabilidad interindividual de las medidas de los distintas variables morfológicas de las cóclea justifica la necesidad de la selección de un implante de características, principalmente longitud, adecuadas para cada paciente de forma que se cubran los requerimientos auditivos de acuerdo a los mapas de distribución tonotópica de las frecuencias calculada por los ángulos de inserción y/o longitud de inserción estimada. La valoración postquirúrgica mediante TCMD de 64 detectores, usando la reconstrucción doble coronal oblicua y midmodiolar, es capaz de evaluar la posición, longitud y profundidad global de toda la guía portadora de electrodos así como de cada electrodo individualmente sin artefactos significativos lo que permite diseñar unas estrategias de programación de acuerdo a las necesidades auditivas y la sección de frecuencias específicas para cada paciente.
spa
dc.description.abstract
Cochlear implants are transducers devices that transform the acoustic signals into electrical ones to stimulate the cochlear nerve. They are indicated in those patients that suffer a unilateral or bilateral, deep or severe, neurosensorial deafness, that do not benefit from an auditory prostheses. CT and a MR of the temporal bone are mandatory in the pre-surgical evaluation of cochlear implant candidates. The development of the 64 detector CT, has improved the image quality as it can perform sections up to 0,625 mm thick (allowing a detailed study of the anatomy of the ear), the achievement of 2D multiplanar linear or curve reconstructions, virtual endoscopic navigation or 3D images. Nowadays cochlear implants of different lengths are available. High resolution imaging techniques and image post processing software’s are necessary to perform an accurate analysis of the cochlear morphology and its length, which allows to select the most suitable implant (in terms of form, length and number of electrodes) for each patient and to determine the depth of suitable insertion. The hypothesis of this dissertation was that the MDCT allows to measure the length of the cochlea accurately with the purpose of selecting the most suitable implant size for each patient in order to obtain the best possible auditory results. The main objectives of the present thesis were: to study the radiological anatomy of the structures of the temporal bone involved in the implantation process. To validate the calculation method of the cochlear and implant length from the standard ear MDCT studies. The secondary objectives were: to determine what variables (anatomical, epidemiologic, radiological and/or surgical) are related to the best auditory results in the implanted patients. To evaluate which is the best post processing software that allows the most accurate measurement of the cochlear and /or implant length. An observational , retrospective study was carry out ; 50 implanted patients, from January 2007 until June 2014, in Hospital Universitari Germans i Pujol that fulfilled all the inclusion criteria and none of exclusion, were selected. Anatomic, radiologic, epidemiologic, surgical and functional variables were collected. The obtained results allowed to conclude that the inter-individual measurement’s variability of the different morphologic variables of the cochlea justifies the need of selecting an implant with the adequate characteristics, principally length, adapted for every patient so that the auditory requests are covered in accordance with the tonotopic distribution frequencies maps calculated by means of insertion angles and/or insertion length. The postsurgical evaluation by means of 64 CT, using the double coronal oblique and midmodiolar reconstructions, is capable of evaluating the position, length and global depth of the whole carrying guide of electrodes as well as of every electrode individually without significant gadgetry what allows to design a strategies of programming in accordance with the auditory needs and the section of specific frequencies for every patient.
eng
dc.format.extent
206 p.
cat
dc.format.mimetype
application/pdf
dc.language.iso
spa
cat
dc.publisher
Universitat Autònoma de Barcelona
dc.rights.license
L'accés als continguts d'aquesta tesi queda condicionat a l'acceptació de les condicions d'ús establertes per la següent llicència Creative Commons: http://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.rights.uri
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
*
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Implants coclears
cat
dc.subject
Implantes cocleares
cat
dc.subject
Cochlear implants
cat
dc.subject.other
Ciències de la Salut
cat
dc.title
Efectividad clínica de la tomografía computarizada de 64 detectores en el estudio pre y postquirúrgico de pacientes candidatos y portadores de implantes cocleares respectivamente
cat
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
61
cat
dc.contributor.authoremail
ppuyalto.germanstrias@gencat.cat
cat
dc.contributor.director
Miró Castillo, Núria
dc.contributor.director
Sánchez Fernández, Juan José
dc.contributor.tutor
Monreal Bosch, Manuel
dc.embargo.terms
cap
cat
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
dc.identifier.dl
B-19729-2015


Documents

ppdp1de1.pdf

3.736Mb PDF

This item appears in the following Collection(s)