New micro pattern gas detector for x-ray diffraction experiments in the sub-millisecond time scale

dc.contributor
Universitat Autònoma de Barcelona. Departament de Física
dc.contributor.author
Fernàndez Banqué, Ferran
dc.date.accessioned
2011-04-12T14:16:29Z
dc.date.available
2007-10-05
dc.date.issued
2007-04-11
dc.date.submitted
2007-10-05
dc.identifier.isbn
9788469067722
dc.identifier.uri
http://www.tdx.cat/TDX-1005107-164748
dc.identifier.uri
http://hdl.handle.net/10803/3387
dc.description.abstract
En instal·lacions de radiació sincrotró, es necessiten detectors amb una bona resolució espacial i un alt ritme de contes local per tal de dur a terme experiments de difracció de raigs x en l'escala temporal del mil·lisegon. Els detectors de gas de micro-fabricació (MPGD) poden satisfer aquests requeriments gràcies a l'alta densitat d'elèctrodes que presenten. No obstant aquest tipus de detectors presenten dos grans problemes: descàrregues elèctriques destructives i un deteriorament continu durant el seu us continuat.<br/>En aquest treball presentem una nova estructura de MPGD: el Micro Reading Mesh Chamber (MRMC). És un MPGD amb un estadi d'amplificació. El detector està dividit en dues regions: la regió de deriva i la regió de multiplicació. Aquestes estan separades per una malla formada per elèctrodes de lectura. El pla de l'ànode té una capa de material resistiu a la seva superfície.<br/>El disseny del MRMC redueix els problemes que els actuals MPGD presenten. Entre d'altres avantatges, el posicionament dels elèctrodes de lectura a la malla incrementa la sensibilitat dels càtodes a la senyal. Això permet una reducció de la intensitat del camp elèctric de multiplicació. En conseqüència, la càrrega del detector i la probabilitat de descàrregues destructives es redueix.<br/>S'han realitzat diverses simulacions per tal d'avaluar i optimitzar el rendiment del detector. Degut al gran nombre de paràmetres que poden ser escollits i del gran nombre de característiques que en depenen, s'ha realitzat un treball de simulació i optimització global. En primer lloc, s'ha dissenyat un programa basat en tècniques Monte-Carlo per tal de simular el procés de detecció i poder així avaluar la resolució espacial en funció dels diferents paràmetres del detector. En segon lloc, s'han realitzat una sèrie de simulacions que involucren la simulació del moviment en tres dimensions de les càrregues i la seva multiplicació dins l'estructura de detecció. Aquests estudis inclouen la estimació de la transparència de la malla, l'estudi de les línies i els temps de deriva dels ions, i la simulació del procés d'allau. Part d'aquestes simulacions han estat verificades experimentalment. Finalment, les capacitancies entre els elèctrodes i l'ànode i entre elèctrodes s'ha simulat per tal d'avaluar el soroll electrònic i els efectes de "crosstalk".<br/>S'ha construït i provat un prototip. Els tests realitzats mostren una bona concordança amb les simulacions del guany. Així doncs, queda demostrat que el MRMC pot arribar a ritmes de contatge local >1.25·105Hz/mm2. No obstant, s'observen guspires en el detector degut a la presència de material dielèctric a la superfície dels càtodes. Degut a la superfície resistiva i la robustesa de l'estructura, el detector ha resistit les descàrregues sense rebre ningun dany. En conseqüència, per tal de que el MRMC esdevingui un detector útil, s'han de millorar tant el procediment de construcció, com les tècniques de neteja.<br/>En conclusió, es necessita més treball experimental per tal d'obtenir un detector lliure de descàrregues completament funcional pel qual les simulacions prediuen un alt ritme de comptes local (>1.25·105Hz/mm2) i una bona resolució espacial (>250?m).
cat
dc.description.abstract
At synchrotron radiation facilities, detectors with high spatial resolution and high local count rate are needed in order to perform x-ray diffraction/scattering on time resolved experiments on the sub-millisecond time scale. Micro Pattern Gas Detectors (MPGD) could provide good spatial resolutions and high count rate thanks to their small cells of amplification region. Despite their promising performance, two major problems have arisen: rare but damaging discharges and, slow but continuous deterioration (aging) during sustained irradiation<br/>Here we present a new MPGD structure: the Micro Reading Mesh Chamber (MRMC). It is a one stage amplification MPGD. It is divided in two regions: the drift/conversion region and the multiplication region. They are separated by a mesh formed by thick (25?m) pick-up strips. The anode plane has a resistive layer on it.<br/>The design of the MRMC reduces the problems that the present MPGD show. Among other advantages, placing the pick-up strips at the mesh, instead of at another readout plane, increases the signal sensitivity of the cathodes. It allows a decrease of the gain through a reduction of the multiplication field. Therefore, it reduces the charging up and the probability of voltage and rate-induced dielectric breakdown.<br/>Different simulations have been carried out to evaluate and optimize the performance of the detector. Due to the large number of detector parameters that can be chosen, and the features that depend on them, a global simulation was done. Firstly, a Monte-Carlo based program that reproduces the detection in the chamber has been developed in order to simulate the spatial resolution as a function of different parameters of the detector. Secondly, a set of studies that involve the simulation of the three dimensional movement of the charges in the chamber and its multiplication have been carried out. These models include the estimation of the mesh transparency, the study of the ion drift paths and times, and the simulation of the avalanche process. Part of these simulations has been cross-checked experimentally. Finally, the capacitances between the strips and the anode, and between strips has been simulated in order to evaluate the electronic noise and the crosstalk effects.<br/>After the simulation work, a prototype was built and tested. The tests show good agreement between the simulated and the experimental gain. This agreement on the space charge calculations demonstrates that the MRMC can deliver local count rates >1.25·105Hz/mm2. Moreover, due to the resistive layer and the strength of the structure, the detector survived without noticeable damage. However, the detector suffers from discharges because of dielectric deposits on the cathode surface. Therefore, to turn this device into a detector for routine use, it will be necessary to both improve the construction process of the mesh structure and to develop an exhaustive cleaning procedure.<br/>In conclusion, more experimental work is necessary to obtain a spark protected functional detector for which the simulations predict a high local count rate (>1.25·105Hz/mm2) and a good spatial resolution).
cat
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Universitat Autònoma de Barcelona
dc.rights.license
ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
dc.source
TDX (Tesis Doctorals en Xarxa)
dc.subject
Raigs-X
dc.subject
Sincrotó
dc.subject
Detectors
dc.subject.other
Ciències Experimentals
dc.title
New micro pattern gas detector for x-ray diffraction experiments in the sub-millisecond time scale
dc.type
info:eu-repo/semantics/doctoralThesis
dc.type
info:eu-repo/semantics/publishedVersion
dc.subject.udc
539
cat
dc.contributor.authoremail
ferran.fernandez@cells.es
dc.contributor.director
Ramos Lerate, Inmaculada
dc.contributor.tutor
Pascual de Sans, Ramón
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
cat
dc.identifier.dl
B-30427-2007


Documents

ffb1de1.pdf

3.169Mb PDF

This item appears in the following Collection(s)